UEI KM9106/P KM 9106 P Quintox Combustion Analyzer O2 CO Meters Tester |
The UEI KM9106/P Combustion Analyzer measures emissions and combustion efficiency from any residential, commercial, or industrial heating appliance.
|
|
It can be configured to measure engine exhaust emissions to provide the complete information required by your air regulatory authority. The KM9106/P is easy to operate and features easily changeable particle and SO2 filters, rechargeable battery with AC power pack, and an integral printer. You can upgrade the standard unit to meet the demanding needs of your professional environment.
KM9106/P Features
-
Measures O2 and CO from 0 to 10,000 parts per million
-
Calculates net stack temperature, efficiency, losses, and CO2
-
Integral printer
-
15 foot long handset cable
-
15 foot probe hose with 1,000 degree Fahrenheit, 12” probe shaft
-
Nearly 2000 test memory slots
-
Durable locking case
-
AC power back
-
1 year limited warranty
-
2 year limited warranty on O2 sensor |
| Specifications |
| Parameter |
Resolution |
Accuracy |
Range |
| Temp. Measurement |
0.1 degree C/ F |
±1 degree F/C,
±0.3 percent of rdg |
32 - 2140 degrees F* |
| Gas Measurement |
| Oxygen (O2) 2 year warranty |
0.10 percent |
0.1/+ 0.2 percent |
0 - 25 percent |
| Carbon Monoxide (CO) Hydrogen compensated |
1 ppm |
± 20 ppm <400 ppm
±5 percent of rdg <2000 ppm
±10 percent of rdg >2000ppm |
0 - 10,000 ppm |
| Carbon Dioxide (CO2) Calculated |
0.10 percent |
± 0.20 percent |
0 - fuel value |
| Nitric Oxide (NO) Nitrogen Dioxide (NO2) Sulphur Dioxide (SO2) |
1 ppm |
±5 ppm <100 ppm
±5 percent of rdg >100 ppm |
Listed in optional sensor section |
| Hydrocarbons (CH4) |
0.01 percent |
<1 percent: ±0.05 percent >1 percent: ±5 percent of reading |
| Pressure (draft) |
0.01 mbar/in WG |
±0.05 percent full scale |
| Optional Sensors |
| KMNO1/ Q |
Nitric Oxide sensor |
0 - 5,000 ppm |
| KM2N01/ Q |
Nitric Oxide sensor |
0 - 10,000 ppm |
| KMNO2/ Q |
Nitrogen Dioxide sensor |
0 - 1,000 ppm |
| KMSO2/ Q |
Sulphur Dioxide sensor |
0 - 5,000 ppm |
| KMHC103/ Q |
Hydrocarbon sensor |
0 - 5 percent LEL ( Methane) |
| KMPS 2 ? Q |
Pressure sensor (draft) |
0 - 150 mbar |
| Dimensions |
17.75 long x 9 wide x 13.75 high in inches |
| Weight |
21 pounds |
*Use high temperature probe over 1,112°F |
| |
|