AC Tool Supply has the guaranteed lowest prices on trusted brand name quality tools and test equipment. 877-207-1244
Contact Us
Internet Payments

Net 30 Day payment terms
0 item(s) | TOTAL: $0 view cart
Home Blog My Account Contact Us About Us Shipment Tracking Terms & Conditions GSA Orders Financing / Leasing International Customers
Request a Quote OSHA / ANSI Safety Guide Canada Customers Faxing Purchase Orders Privacy Policy Price Match Guarantee
Balometer - Flow Hood
Infrared IR Camera
AEMC
Alnor Balometers
Bacharach
Capital Safety DBI-SALA
Chauvin Arnoux
Combustion Analyzers
Construction Lasers
Cool Machines Inc.
Duct Register Cover Products
Enerac Combustion Analyzers
Energy Audit Package Deals
Energy Auditing Software
Extech Instruments
Fantech
Gardner Bender
Geocel Sealant Solutions
Hioki
Ideal Electrical
Infrared Camera
Infrared Thermography Training
Insulation Blowing Machines
Intec Insulation Blowers
Irwin Industrial Tools
Kanomax
Knipex Hand Tools
Krendl Insulation Blowers
Leica Disto Geosystems
Met One Instruments
Miller Fall Protection
Nikro
OSHA & ANSI Safety Products
Pacific Laser Systems
Spray Foam Insulation
Retrotec Blower Door Systems
Skil Saw & Tools
Speciality Tools
Stabila Laser Level Tools
Test Products International
Testo Test and Measurement
Training / Certification
Tramex Mositure Meters
TSI Flow Hoods
UEI Instruments
Wohler Instruments
FLIR Infrared Thermal Camera
Particle Counter
LED LIghts
TIF
Solar Tools and Meters
IECC International Energy Conservation Code
2015 IECC International Energy Conservation Code
2018 IECC International Energy Conservation Code
Zipwall
Flow Hood - Balometer
Infrared Camera Rental
Insulation Machine
Used Insulation Equipment
3M
AC Tool
Accuform Signs
Advanced Cable Ties
AEMC
Air Systems International
Airy Technology
Allegro Industries
Bacharach
Bradley
Building Health Check, L.L.C.
Bullard
Can-Filters
Capital Safety
Carlisle
Chicago Protective
Cool Machines
CorDEX Instruments
DeWALT
DuPont
E Instruments
Enerac
Falltech
Fantech
Fieldpiece
Generac
General Floorcraft
Gillette Generators
Greentech
Guardian
Hardcast
Hipotronics
Honeywell
IMR Environmental Equipment Inc.
Infraspection Institute
Insulation Machine Corp IMC
Intec
Irwin
Kanomax
Kimo
Knipex
Krendl
Lighthouse
mavcap
Met One Instruments
Miller
MSA Safety
NIKRO Industries, Inc.
Novatek
NWi Northwest Instrument
Oberon Safety
Pacific Laser Systems
Pro Built Tools
Protective Industrial Products, Inc.
Radians
Rapid Care
Reed
REGIN
Retrotec
Ridge Rock
Robinair HVAC
Safewaze
Salisbury
Schaefer Ventilation Equipment
SENSIT Tech.
Set Go
TEC
TED
Test Products International
TPI Corporation
Tramex
UEI
Vitrek
Voltec
Wera Tools, Inc.
Zipwall

UEI C157KIT Eagle 3X EOS Xtended Life Combustion System Analyzer NOx CO CO2 O2
 
Product Information

C155 Datasheet C157 Datasheet
  C155 Owners Manual C157 Owners Manual

Your Price: $2,095.95
$1,997.95
Quantity

UEI C157KIT Eagle 3X EOS Xtended Life Combustion System Analyzer NOx CO CO2 O2

The new UEI Eagle 3X Xtended Life Combustion System Analyzer has a revolutionary new design that eliminates the number one dreaded hassle for combustion contractors which is the yearly calibration and replacement of the O2 sensor.

 

By replacing the traditional electro chemical O2 sensor with the innovative EOS Technology CO2 sensor, the EAGLE 3X now makes direct CO2 measurements and then calculates the O2 level. The cost of ownership is thus lowered by eliminating the yearly replacement of the O2 sensor and minimizing calibration drifting typically found with traditional electro chemical sensors. The new EOS Technology sensor has a 5 year warranty and has an unsurpassed industry leading life span of a phenomenal 10 years.

 

C157KIT Features

  • Measures:
    • Differential flue temperature
    • Carbon Dioxide CO2
    • Flue and ambient carbon monoxide CO and Differential Pressure
    • Nitric Oxide NOx
  • Calculates:
    • Oxygen
    • Gross - net efficiency
    • Excess air
    • CO air free
  • Work light
  • Four line backlit LCD display
  • 179 memory positions
  • User customizable parameters view
  • Individual report printouts
  • DMM style rotary selector
  • Protective boot with integral magnet
  • Real time clock
  • CO readings to 1 part per million
  • Infrared printer port
  • 5 year limited warranty
  • 5 year warranty on sensor

 

Measures, Calculates* or Displays

  • Oxygen O2*
  • Carbon Monoxide CO
  • Carbon Dioxide CO2
  • Combustion efficiency*
  • Pressure - draft
  • Date and time
  • Temperature - flue, inlet, and net*
  • Excess air*
  • CO Air Free*
  • Battery level
  • Fuel type
  • Nitric Oxide NOx

 

C157KIT Analyzer Kit Includes

  • KMIRP2 Infrared Thermal Printer
  • 2 K-Type Temperature Probe

  • Flue Probe
  • 2 Static Pressure Hoses
  • True Draft Probe
  • Gas Pressure Probe
  • AACA4 AC Adapter
  • AC509 Hard Carrying Case
  • Thermal printer paper roll
  • Particle Filter
  • Batteries
  • Quick Start Guide
  • Owners Manual
Specifications

Temperature

EAGLE X: C155 & C157

Flue Temp Range

20~2400°F (-29~1315°C)

Inlet Temperature (probe - T2)

20~2400°F (-29~1315°C)

Inlet Temperature (ambient)

32~112°F (0~50°C)

Net Temperature (ÆT)**

20~2400°F (-29~1315°C)

Resolution

0.1°C/F

Flue (T1, Inlet T2 & ÆT) Accuracy

±(0.3% rdg +3.6°F(2°C))

Inlet Temperature Accuracy

±(0.3% rdg +1.8°F(1°C))

Gas

Oxygen

0~21%**

O2 resolution / accuracy

0.1% / ±0.3%

Carbon Monoxide (CO)

0~2000 ppm

(4000 max 15 min)*

CO resolution / accuracy

1 ppm / ±10 ppm<100ppm,

±5% rdg>100ppm

Carbon Dioxide (CO2)

0~20%*

CO2 resolution / accuracy

0.1% / ±2%

Efficiency resolution/accuracy

0.1% / ±3%

Excess Air**

0~250%**

Excess Air resolution/accuracy

0.1% / ±3%

CO/CO2 ratio**

0~0.999

CO/CO2 resolution/accuracy

0.001 / ± 5% rdg

Nitric Oxide (NO1)***

0~100 ppm

NO1 resolution/accuracy***

±2 ppm <30ppm
±5ppm <100ppm

Pressure

Range

Accuracy

±0.08” wc (±0.2mBar)

2±0.002” wc (±0.005mBar)

±0.4” wc (±1mBar)

±0.01” wc (±0.03mBar)

±32” wc (±80mBar)

±3% rdg

Resolution

0.001” wc < 9.999” wc

 

0.01” wc >10.00” wc

 

0.001mBar<24.999mBar

 

0.01mBar > 25 mBar

* Measured at STP (standard temperature and pressure)
** Calculated value
*** NO1 sensor installed on C157. Available as an upgrade for C155.
Gas Zero (Fresh Air Zero) - Is a reset procedure to maintain accurate readings
from the EOS sensor. This procedure compensates for any change in ambient
conditions that may impact the readings.
 Related Items
Bosch RDN6V 6 Inch 5/8 TPI Demolition Reciprocating Sawzall Blades
$4.03
Add To Cart
Novatek 139.0215 Electric Peening Prep Kit 2" Rotopeen Flaps Star Cutters
$1,995.00
Add To Cart
Kimo CAL 300 Sound Level Meter Acoustic Calibrator
$694.96
Add To Cart

Home

About Us

Contact Us

My Account

Secured By Rapid SSL $10,000 Warranty




Copyright © AC Tool Supply Inc. All Rights Reserved.