Technical Data |
|
Image specifications |
|
Physical characteristics |
|
|
Infrared |
|
Weight |
32 ounces |
|
Optical field/minimum focus distance |
32 x 24 degrees / 0,1 m (standard lens) 12 x 9 degrees / 0,6 m (telephoto lens) |
Dimensions |
6 x 4.25 x 10.5 inches |
|
Thermal sensitivity (NETD) |
<0,1 degrees C at 30 degrees C |
Tripod mounting |
yes, with adapter, included in delivery |
|
Geometric resolution |
3,5 mrad (standard lens)
1,3 mrad (telephoto lens) |
Housing |
ABS, diecast zinc |
|
Image refresh rate |
9 Hz outside, 33 Hz inside EU |
PC software
System requirements |
Windows XP (Service Pack 2), Windows Vista, interface USB 2.0 |
|
Focus |
manual + motorized |
Norms, tests, warranty |
|
|
Detector type |
FPA 160 x 120 pixels,
a.Si, temperature-stabilized |
EU guideline |
2004 / 108 / EG |
|
Spectral range |
8 to 14 μm |
Warranty |
2 years |
|
Visual |
|
Image storage |
|
|
Optical field/min. focus distance |
33,2 x 25,2 degrees / 0,4 m |
File format |
.bmt; export possibility to in .bmp, .jpg, .csv |
|
Image size |
640 x 480 Pixels |
Data storage device |
SD card |
|
Image refresh rate |
8 ... 15 Hz |
Storage capacity |
1 GB (approx. 800-1,000 images) |
|
Image presentation |
|
Optics |
|
|
Image display |
3.5 inch LCD with 320 x 240 Pixels |
Standard lens (32 degrees) |
yes |
|
Display options |
IR image only
real image only
IR and real image |
Telephoto lens (12 degrees) |
yes, optional |
|
Video output |
USB 2.0 |
Laser measurement spot marking |
|
|
Video stream |
25 Hz |
Classification of laser |
635nm, Class 2 |
|
Color palettes |
8 options |
Current supply |
|
|
Measurement |
|
Battery type |
Fast charging, Li-ion battery, changeable on site |
|
Temperature range |
-20 to +100 degrees C
0 to +350 degrees C (switchable) |
Operating time |
approx 5 hours at 20 degrees C |
|
Accuracy |
±2 degrees C, ±2 percent of mv |
Charging options |
in instrument/charger (optional) |
|
Minimum diameter measurement point |
10 mm at 1 m (standard lens),
standard 4 mm at 1 m (telephoto lens) |
Mains operation |
yes |
|
Switch on time |
40 se conds |
Output voltage |
5 V / 4 A |
|
Humidity measurement and air temperature measurement with wireless probe (optional) |
0 to 100 percent RH / -20 to +70 degrees C td
-20 to +70 degrees C (air temperature with NTC) |
Ambient conditions |
|
|
Accuracy wireless probe |
±2 percent RH / ±0,5 degrees C (air temperature) |
Operating temperature range |
-15 to +40 degrees C |
|
Measurement functions |
Standard measurement (1-point), 2-point measurement, Hot/Cold Spot recognition
Display of surface moisture distribution via manual input of humidity
Optional humidity measurement withwireless humidity probe |
Storage temperature range |
-30 to +60 degrees C |
|
Reflected temperature compensation |
manual |
Air humidity |
20 to 80 percent RH non-condensing |
|
Setting emissivity |
Nine materials programmable,
of which one user-defined (0.01 - 1.0) |
Protection class of housing |
IP54 |