AC Tool Supply has the guaranteed lowest prices on trusted brand name quality tools and test equipment. 877-207-1244
Contact Us
Internet Payments

Net 30 Day payment terms
0 item(s) | TOTAL: $0 view cart
Home Blog My Account Contact Us About Us Shipment Tracking Terms & Conditions GSA Orders Financing / Leasing International Customers
Request a Quote OSHA / ANSI Safety Guide Canada Customers Faxing Purchase Orders Privacy Policy Price Match Guarantee
Balometer - Flow Hood
Infrared IR Camera
AEMC
Alnor Balometers
Bacharach
Capital Safety DBI-SALA
Chauvin Arnoux
Combustion Analyzers
Construction Lasers
Cool Machines Inc.
Duct Register Cover Products
Enerac Combustion Analyzers
Energy Audit Package Deals
Energy Auditing Software
Extech Instruments
Fantech
Gardner Bender
Geocel Sealant Solutions
Hioki
Ideal Electrical
Infrared Camera
Infrared Thermography Training
Insulation Blowing Machines
Intec Insulation Blowers
Irwin Industrial Tools
Kanomax
Knipex Hand Tools
Krendl Insulation Blowers
Leica Disto Geosystems
Met One Instruments
Miller Fall Protection
Nikro
OSHA & ANSI Safety Products
Pacific Laser Systems
Spray Foam Insulation
Retrotec Blower Door Systems
Skil Saw & Tools
Speciality Tools
Stabila Laser Level Tools
Test Products International
Testo Test and Measurement
Training / Certification
Tramex Mositure Meters
TSI Flow Hoods
UEI Instruments
Wohler Instruments
FLIR Infrared Thermal Camera
Particle Counter
LED LIghts
TIF
Solar Tools and Meters
IECC International Energy Conservation Code
2015 IECC International Energy Conservation Code
2018 IECC International Energy Conservation Code
Zipwall
Flow Hood - Balometer
Infrared Camera Rental
Insulation Machine
Used Insulation Equipment
3M
AC Tool
Accuform Signs
Advanced Cable Ties
AEMC
Air Systems International
Airy Technology
Allegro Industries
Bacharach
Bradley
Building Health Check, L.L.C.
Bullard
Can-Filters
Capital Safety
Carlisle
Chicago Protective
Cool Machines
CorDEX Instruments
DeWALT
DuPont
E Instruments
Enerac
Falltech
Fantech
Fieldpiece
Generac
General Floorcraft
Gillette Generators
Greentech
Guardian
Hardcast
Hipotronics
Honeywell
IMR Environmental Equipment Inc.
Infraspection Institute
Insulation Machine Corp IMC
Intec
Irwin
Kanomax
Kimo
Knipex
Krendl
Lighthouse
mavcap
Met One Instruments
Miller
MSA Safety
NIKRO Industries, Inc.
Novatek
NWi Northwest Instrument
Oberon Safety
Pacific Laser Systems
Pro Built Tools
Protective Industrial Products, Inc.
Radians
Rapid Care
Reed
REGIN
Retrotec
Ridge Rock
Robinair HVAC
Safewaze
Salisbury
Schaefer Ventilation Equipment
SENSIT Tech.
Set Go
TEC
TED
Test Products International
TPI Corporation
Tramex
UEI
Vitrek
Voltec
Wera Tools, Inc.
Zipwall

IMR Environmental 2800-5 28000-5-SP Combustion Gas Analyzer CO O2 NOx CO2
IMR Environmental 2800-5 28000-5-SP Combustion Gas Analyzer CO O2 NOx CO2
 
Product Resources

 IMR Environmental 2800-5 28000-5-SP Combustion Gas Analyzer CO O2 NOx CO2

Your Price:
$4,950.00
Quantity

IMR Environmental 2800-5 28000-5-SP Combustion Gas Analyzer CO O2 NOx CO2

IMR Environmental Equipment 2800 5 has the newest sensor technology for precision flue gas measurements and longer lifetime.

IMR's 28000-5-SP has an optimum interior design which provides you with easier service and better protection for the unit. It continuously & simultaneously measures up to 18 different parameters with a large display for easy reading.

Applications
  • Boilers
  • Burners
  • Engines
  • Turbines
  • Cars
  • Trucks
  • Plants
  • Chemical Industries
  • Steel Plants
  • Refineries
IMR Environmental 2800-5 28000-5-SP Features

Standard
  • Durable aluminum case
  • Simultaneous measurements for O2 - Oxygen, CO - Carbon Monoxide, SO2, HC/CH4, TG - Flue-gas temperature, TA - Ambient Air temperature
  • Parameter calculations
    • Losses / Efficiency, Excess Air / Lambda, CO2 - Carbon Dioxide, NOx
  • 23 programmed fuels, 4 programmable
  • Soot, Draft
  • Automatic zero calibrations
  • Integrated self check program
  • Simultaneously displays parameters on an illuminated display
  • Printer w/ programmable print-out cycle
  • Standard deviation & average value calculations
  • Draft measurement w/ optional upgrades for differential draft & velocity measurements with Pitot tube
  • Unit selections - mg / Nm3, mg / Nm3 (ref O2), ppm
  • Gas sample probe E – 0.8 ft. (250 millimeter) length - hose 8 ft. (2.5 meter) length
  • Rechargeable battery w/ charger
  • 12 VDC Power Jack
  • 110 or 230 Volt power supply
  • User manual
  • RS232
  • Memory
  • 1 year warranty parts + labor
Optional
  • CO High
  • IMR Data software
  • RS232 cable
  • Permeation dryer
  • 300 or 610 Lg pitot tubes
  • Longer gas probes
    • 750 mm Type E or S
    • 1500 mm Type E or S
  • High temperature probe upgrades
    • 250 mm
    • 750 mm
    • 1500 mm

 IMR Environmental 2800-5 28000-5-SP Specifications

Parameter
Principle
Resolution
Accuracy
Range
Standard
O2 OxygenElectro chemical cell
0.1 Vol.%+/- 0.2 Vol. %0-20.9 Vol. %X
CO Carbon monoxideElectro-chemical cell
1 ppm
Z
0-2000/4000ppm
X
CO High
(NDIR Optional)0.001 Vol.%Z
0-10/20 Vol.%
CO2 Carbon dioxide
NDIR
0.01 Vol.%+/- 0.2 Vol. %0-20 Vol. %

CO2 Carbon dioxideCalculation0.1 Vol.%+/- 0.2 Vol. %0- CO2 max
X
HC/CH4 HydrocarbonsPellistor or NDIR
0.1 Vol.%Z
0-100% LEL
X
NO Nitric oxideElectro chemical cell1 ppm
Z
0-2000 ppm

NO2 Nitrogen dioxide
Electro chemical cell1 ppmZ
0-100 ppm
SO2 Sulfur dioxide
Electro chemical cell1 ppmZ
0-4000 ppmX
H2S Hydrogen SulfideElectro chemical cell1 ppmZ
0-200 ppm
TG Flue gas temperature
NiCr-Ni thermocouple
1 K
+/- 2%
-4°F - 2192°F
0°C - 1200°C
X
TA Air temperature
Semiconductor1 K
+/- 0.2 K
 -4°F / 248°F
0°C - 120°C
X
P Draft
Solid state0.01 hPa+/- 2% +/- 40 hPa
X
NOx Nitrogen oxides
Calculation1 ppm
Z
0-NOx max
X
NH3 Ammonia
Electro-chemical
1 ppmZ
0-1000/5000 ppm

N2O Nitrous OxideNDIR0.001 Vol. %Z
0-1 Vol. %

HCl Hydrogen ChlorideElectro-chemical1 ppmZ
0-200 ppm

Cl2 Chlorine
Electro-chemical1 ppmZ
0-5000 ppm
H2 HydrogenElectro-chemical1 ppmZ
0-10000 ppm
Losses / Efficiency
Calculation
0.1 %
+/- 0.1 %
0-99.9 %
X
Excess Air / Lambda
Calculation0.1 %+/- 0.1 %1.0-9.99
X
Soot
Filter paper method

  0-9X
Velocity with Pitot tube
Solid state
0.01 m/s
+/- 2%
0-80 m/s

RPM Meter
Solid state100 RPM
+/- 2%180-10000 RPM

** Different/customized ranges available. Equipped with a maximum of 8 gas sensors

Z = 0 - 20 % of whole measurement range ± 5 %
 21 - 100 % of whole measurement range ± 1 % of displayed measurement
Choose Options and Quantity
High Temp. Gas Probes High Temperature 250 mm gas probe [+$540.00]
High Temperature 750 mm gas probe [+$2,750.00]
High Temperature 1500 mm gas probe [+$2,990.00]
Longer Gas Probes 750 mm Type E [+$480.00]
750 mm Type S [+$580.00]
1500 mm Type E [+$590.00]
1500 mm Type S [+$690.00]
Options Draft / Diff [+$225.00]
Soot [+$450.00]
Pitot Tubes 300 Lg pitot tube [+$447.00]
600 Lg pitot tube [+$547.00]
Accessories Permeation Dryer [+$2,200.00]
RS232 Cable [+$60.00]
IMR Data Software [+$540.00]
IMR Environmental 2800-5 28000-5-SP Combustion Gas Analyzer CO O2 NOx CO2
 Related Items
Fieldpiece SRL8 Heated Diode Refrigerant Leak Detector CFC HFC HCFC
$231.88
Add To Cart
Allegro 9401-26 9401 26 Magnetic Manhole Lid Lifter Steel 900 lb
$1,306.00
Add To Cart
Snap On 870785 2000 PSI Electric Pressure Power Washer
$288.55
Add To Cart

Home

About Us

Contact Us

My Account

Secured By Rapid SSL $10,000 Warranty




Copyright © AC Tool Supply Inc. All Rights Reserved.