AC Tool Supply has the guaranteed lowest prices on trusted brand name quality tools and test equipment. 877-207-1244
Contact Us
Internet Payments

Net 30 Day payment terms
0 item(s) | TOTAL: $0 view cart
Home Blog My Account Contact Us About Us Shipment Tracking Terms & Conditions GSA Orders Financing / Leasing International Customers
Request a Quote OSHA / ANSI Safety Guide Canada Customers Faxing Purchase Orders Privacy Policy Price Match Guarantee
Insulation Vacuum Systems
Bacharach
Capital Safety DBI-SALA
Infrared Thermography Training
Insulation Blowing Machines
Intec Insulation Blowers
Knipex Hand Tools
Krendl Insulation Blowers
Met One Instruments
Miller Fall Protection
Nikro
OSHA & ANSI Safety Products
Speciality Tools
IECC International Energy Conservation Code
2015 IECC International Energy Conservation Code
2018 IECC International Energy Conservation Code
Insulation Machine
Used Insulation Equipment
3M
Advanced Cable Ties
AEMC
Air Systems International
Allegro Industries
Bacharach
Bradley
Bullard
Can-Filters
Capital Safety
Chicago Protective
Cool Machines
CorDEX Instruments
DeWALT
E Instruments
Falltech
Generac
General Floorcraft
Gillette Generators
Greentech
Guardian
Honeywell
Infraspection Institute
Insulation Machine Corp IMC
Intec
Kimo
Knipex
Krendl
Met One Instruments
Miller
MSA Safety
NIKRO Industries, Inc.
Novatek
Oberon Safety
Pro Built Tools
Radians
Rapid Care
Reed
Salisbury
Schaefer Ventilation Equipment

E Instruments E8500 E 8500 Flue Gas Emissions Combustion Analyzer
E Instruments E8500 Flue Gas Emissions Combustion Analyzer
 
Product Resources

 

  E Instruments E8500 Datasheet E Instruments E8500 Datasheet
 
E Instruments E8500 Flue Gas Emissions Combustion Analyzer

Your Price:
$0.01
Availability:
Not for Sale

E Instruments E8500 E 8500 Flue Gas Emissions Combustion Analyzer NOx CO2

The E8500 from E Instruments is unsurpassed as the most advanced and powerful portable combustion gas analyzer available on today's market, & is a portable test instrument for EPA compliance of emissions monitoring.

The E8500 Industrial flue gas analyzer can also test and monitor furnaces, boilers, engines, and has many other combustion and emissions applications. A built in thermoelectric chiller quickly and efficiently removes water vapors from flue gas samples to prevent combustion gas bubbling from gas phase into condensate. The E8500 chiller is made for exceptional sample conditioning & handles flue gases to 40 percent water content. The built in drain pump for condensate automatically pumps accumulated water through the bottom for improved convenience, especially if used for long term monitoring and testing.
 
The E8500 may have 9 gas sensors total as a combination of 6 electrochemical & 3 NDIR sensors.
 
E8500 Includes
  • Condensate automatic drain pump
  • Thermoelectric chiller built in
  • NO, CO & O2 sensors
  • Rechargeable battery pack
  • 110 - 240 Volts AC / 50 - 60 Hertz battery charger
  • 12 Inch (300 millimeter) test probe w/ 10 foot (3 meter) dual hose
  • Air temperature & stack gas measurements
  • Differential & draft measurements
  • Excess air, efficiency and CO2 calculations
  • Internal memory (1000 test results) to use with long term data logging and monitoring
  • Real time software w/ Bluetooth for PC includes real time reports, graphing and data logging
  • USB cable
  • Wireless communication
  • Operator's manual
  • Calibration certificate
  • Protective carry case
E Instruments E 8500 Features
  • 6 Different electrochemical sensors available
    • NO2
    • NO
    • CO
    • SO2
    • O2
    • H2S
  • Non dispersive (NDIR) sensors available
    • High CO, CxHy & CO2
  • True NOx measurement
  • Auto range CO dilution for measurements to 20,000 parts per million
  • 2 channel thermometer
  • Optional remote wireless printer
  • Gas velocity measurement using optional pitot tube
  • LCD rotating display
  • Pre calibrated and field replaceable gas sensors
  • Immediate response time
  • 2 channel thermometer
  • Battery pack
  • Metal Unbreakable Hose Connectors

E8500 Specifications

Parameters Sensors Ranges Resolutions Accuracies
O2 Electro-chemical 0 - 25 percent 0.1 percent +/-0.1 percent vol
auto range CO 
Electro-chemical 0 - 20,000 parts per mil. 1 part per mil.
+/-10 percent rdg
CO Electro-chemical 0 - 8,000 parts per mil. 1 part per mil.
below 300 parts per mil.= +/- 10 ppm
to 2000 parts per mil. = +/- 4 percent
above 2000 parts per mil. = +/- 10 percent
CO NDIR 0 to 15 percent 0.01 percent
+/- 3 percent rdg
CO2 Calc. 0 to 99.9 percent 0.1 percent  
CO2 NDIR 0 to 20 percent 0.1 percent
+/- 3 percent rdg
NO Electro-chemical 0 - 4000 parts per mil. 1 part per mil. below 125 parts per mil. = +/- 5 parts per mil.
to 4000 parts per mil. = +/- 4 percent
NO2 Electro-chemical 0 - 1000 parts per mil. 1 part per mil. below 125 parts per mil. = +/- 5 parts per mil.
to 1000 parts per mil. = +/- 4 percent
Low NO2 / Low NO Electro-chemical 0 - 500 parts per mil.
0.1 part per mil.
below 50 parts per mil. = +/- 2 parts per mil.
to 500 parts per mil. = +/- 4 percent
NOx Calc. 0 - 5000 parts per mil. 1 part per mil.
 
SO2 Electro-chemical 0 - 4000 parts per mil 1 part per mil. below 125 parts per mil. = +/- 5 parts per mil.
to 4000 parts per mil. = +/- 4 percent
CxHy NDIR 0 to 3 percent 0.01 percent
+/- 3 percent rdg +/- 0.01 percent
H2S Electro-chemical 0 - 500 parts per mil. 1 part per mil. below 125 parts per mil. = +/- 5 parts per mil.
to 500 parts per mil. = +/- 4 percent
Tair Pt-100
14 - 212 degree F
-10 - 99.9 degree C
1 degree F
1 degree C
+/- 3 degree F
+/- 2 degree C
Tgas Tc K
32 - 1830 deg F
0 - 999.9 deg C
1 degree F
1 degree C
+/- 3 degrees C 
+/- 5 degrees F
ΔT Calc.
32 to 1830 deg. F
0 to 999.9 deg. C
1 degree F
1 degree C
Draft  / Pressure Bridge +/- 0 - 40 inH2O 0.1 in H2O
+/- 1 percent rdg
Excess Air Calc. 1 to infinity 0.01  
Gas Velocity Calc.
0 to 330 feet / sec.
0 to 99.9 meters / sec.
0.1 feet / sec.
0.1 meters / sec
Efficiency Calc. 0 - 99.9 percent
0.1 percent
 

Choose Options and Quantity
Electrochemical Gas Sensors O2 Sensor 0 to 25 percent - (O)
0 to 8000 ppm CO Sensor auto range dilution to 20,000 ppm - (C)
0 to 4000 ppm NO Sensor - (N)
0 to 1000 ppm NO2 Sensor - (D)
0 to 4000 ppm SO2 Sensor - (S)
0 to 500 ppm H2S Sensor - (H)
Non dispersive (NDIR) Sensors CO2 0 to 20%, High CO 0 to 15% and CxHy 0 to 3% Sensors - (ABC)
NDIR sensors (none) - (0)
Sample Test Probes And Hoses 12 Inch (300 millimeter) Test Probe, 1470 F (800 C) maximum w/ 10 foot (3 meter) dual hose - (12)
30 Inch (750 millimeter) Test Probe, 1470 F (800 C) maximum w/ 10 foot (3 meter) dual hose - (30)
40 Inch (1 meter) Test Probe, 2190 F (1200 C) maximum w/ 10 foot (3 meter) Hose - High temp. applications - (40HT)
60 Inch (1.5 meter) Test Probe, 2190 F (1200 C) maximum w/ 10 foot (3 meter) Hose - High temp. applications - (60HT)
 Related Items
MSA Safety 506630 Dynescape Automatic Retractable Descender SST 50Ft
$1,991.25
Add To Cart
Allegro 9538-25 COM-PAX-IAL Axial Explosion Proof Blower Fan 8 Inch
$1,533.75
Add To Cart
MSA Safety 506208 Dyna-Lock Self Retractable Lifeline Galvanized 95 Ft
$1,185.00
Add To Cart

Home

About Us

Contact Us

My Account

Secured By Rapid SSL $10,000 Warranty




Copyright © AC Tool Supply Inc. All Rights Reserved.