Product Information
Testo 560 Brochure AC Applications Guide Residential AC Systems RSA Whitepaper Solar Powered Refrigeration Retrofitting Domestic Refrigeration Systems Refrigeration and AC Systems Refrigeration Systems For Cold Storage
The Testo 0560 5564 556 2 RSA is the stainless steel version for ammonia refrigeration systems, and will need the 0554 5561 Ammonia Adapter.
The temperature and pressure curves of 30 refrigerants are stored in the unit. If other refrigerants are required, they can be downloaded from the Testo website and transferred to the unit free of charge. This makes the Testo 560 1 RSA extremely versatile for all systems and requirements.
Evacuation with the display of the evaporation temperature of water
During the evacuation of a system, the integrated vacuum sensor measures both the absolute pressure and the evaporation temperature of water. The measured values provide information on whether the system is being optimally dried, which means the water vapor is being withdrawn from the system properly. The evacuation can be carried out much faster than has been possible in the past.
The data store in the 560 allows easy and fast documentation of the measurement results. Stored values can be easily logged with the help of our Easy Kool software, in graphical or tabular form. Company logos can be integrated in the reports, further enhancing your professional image. All analyzers have the possibility of printing readings on the Testo infrared report printer.
Easy refrigerant inventory management according to the F gas regulation
The filling or refilling of a system can be documented, and the quantities are stored in the instrument.
A commissioning report can be created if all actions taken during commissioning are recorded. The uninterrupted documentation of the data over a defined period allows the targeted diagnosis of the causes of malfunctions. The commissioning data as well as all inspection data are available at all times. This makes all interference with the system including unauthorized interference transparent. The data are manipulation proof and all relevant data are available.
The Testo 400563 5606 560 1 RSA Deluxe Kit Includes:
*needs the 0554 5561 Ammonia Adapter
Testo 560 1 Technical Data
Operating temperature
-20 degrees C to + 60 degrees C
Storage temperature
Display
LCD
Battery life
40 hours without illumination
Dimensions
10 1/4 x 5 1/8 x 2 3/4 inches
Weight
2.8 pounds
Pressure media
CFC, HFC, N, H2O, CO2, 2 stainless steel versions: NH3
Protection class
IP 54
25/50 barrelrel
Overload (LP/HP)
40/100 bar
Accuracy
± 0.5 percent of full scale value ± 1 digit Class 0.5
Connections
3x7/16 inches – UNF+1x 5/8 inches – UNF
Vacuum
0 to 200hPaabs
Overload vacuum
3bar/sensor protected from high pressures
Temperature
Measuring range
- 50 to + 200 degrees C
Pt 100 class B ± (0.3 + 0.005 tl)
Resolution
0.1 degree C
Probe connections
0.1 2x plug in and 2x wireless
Refrigerants in the instrument
further refrigerants can be downloaded free of charge from the Testo
homepage using the software
Documentation
Data store in instrument
60,000 readings
Refrigerants permanently stored in instruments
R12
R403B
R414b*
R1270
R404A
R417A
R134A
R406a*
R422a*
R22
R407A
R500
R33
R407B
R502
R290
R407C
R507
R401A
R407D
R508**
R401B
R408A
R717**
R401C
R409A
R723**
R402A
R410A
R744
R402B
R413A
R718
* only testo 523 / 556 1 / 560 1 (brass)
** only testo 556 2 / 560 2 (stainless steel)