With efficient measurement due to absolute pressure compensation the Testo 314 independently compensates fluctuations in absolute pressure during volume flow measurement via absolute pressure compensation.
Zeroing phase for connected pipe
To determine ΔP efficiently and quickly, zeroing to ambient air pressure takes place while the measurement is in progress, thus eliminating interruptions and removal of pipes.
Measuring using standard test pressure compensation with feeding unit.
The flow test which is independent of gas mains, has the advantage that pressure fluctuations in pipes can be compensated. The built in flow pressure controller (gas bubble with gas feeding unit) compensates for fluctuations. The finely adjusted value is displayed along with the leakage amount.
314 Gas and Water Leak Analyzer Set Features:
-
Integrated printer
-
Preliminary and main test on gas pipes
-
Pressure drop test on water pipes (high pressure measurement up to 30 bar)
-
Fast measurement of amount of gas leaking according to DVGW-TRGI '86/96 / VP 952
-
Efficient detection of gas leaks using the Testo 316 1
-
Analysis software to show course of measurement
-
Serviceability test on gas pipes
-
Data recording for testing pressure regulator
-
Analysis with PC software
- Preliminary and main test on gas pipes
- Pressure drop test on water pipes (high pressure measurement up to 30 bar)
- Fast measurement of amount of gas leaking according to DVGW-TRGI '86/96 / VP 952
- Efficient detection of gas leaks using the Testo 316 1
- Analysis software to show course of measurement
- Serviceability test on gas pipes
- Data recording for testing pressure regulator
- Analysis with PC software
- testo 314, pressure meter with built in printer, from -1000 mbar to +1000 mbar
- Mains unit 230 V/8 V/1 A for separate use of control unit
- System case including hose set for connection to the gas pipe
- testo 316 1, electronic gas leak detector with flexible measurement probe
- TopSafe for testo 316, indestructible protection case including stand
- Leak detection spray for spraying on gas pipe, bubbles indicate leaking points
- Conical test stop ½ inch for connecting test set to the gas pipe ¾ to 1 1/4 inches
- Conical test stop ¾ inch for connecting test set to the gas pipe 1 to 1.75 inches
- High pressure step plug 3/8 inch and ¾ inch for connecting test set to the gas pipe
- High pressure step plug ½ inch and 1 inch for connecting test set to the gas pipe
- Pressure release plug
- Single valve block for blocking off the pipe
- Double valve brass branch for connecting 2 or more pipes, can be blocked off separately
- Test pump for generating test pressure
|