AC Tool Supply has the lowest prices on trusted brand name quality tools.
Home Energy Audit  BPI Resnet HERS LEED training certification Open 7 days a week
ACToolSupply offers live support from
6am to 9 pm Eastern Time


0 item(s) | TOTAL: $0.00 view cart
Home My Account About Us Contact Us Order/Shipment Tracking Policies, Terms & Conditions GSA Orders Financing / Leasing International Customers
HomeGauge Download Request a Quote Terms and Conditions Canada Customers Faxing Purchase Orders Fluke Free Trial
AC Tool Insulation Machines
ACT Lok
AEMC
Alnor Balometers
Bacharach
Bosch Measuring And Layout
Bosch Power Tools
Chauvin Arnoux
Clean Edison BPI & LEED Training
Combustion Analyzers
Construction Lasers
CST Berger
David White Instruments
Energy Audit Package Deals
Energy Auditing Software
Extech Instruments
Fluke Test Equipment
Gardner Bender
Geocel Sealant Solutions
Ideal Electrical
Insulation Blowing Machines
Intec Insulation Blowers
Irwin Industrial Tools
Knipex Hand Tools
Krendl Insulation Blowers
Leica Disto Geosystems
Makita Drills & Power Tools
Miller Fall Protection
MK Diamond
OSHA & ANSI Safety Products
Retrotec Blower Door Systems
Rotozip
Skil Saw & Tools
Speciality Tools
Stabila Laser Level Tools
Testo Test and Measurement
Tramex Mositure Meters
TSI Flow Hoods
UEI Instruments
Wohler Instruments
Particle Counter
LED LIghts

Home > Retrotec Blower Door Systems
Share |
Retrotec R31 Duct Testing Blower System
Retrotec R31 Duct Testing Blower System
 

Product Information

  R31 Specifications R31 Specifications
  Blower Door Testing Blower Door Testing
  Building Pressurization Building Pressurization
  Blower Doors and Duct Blasters Blower Doors and Duct Blasters
  Using Blower Door Data Using Blower Door Data


Price
Your Price:
$2,133.00
Quantity
 
 Description

Retrotec R31 Economy Duct Testing Duct Blower system with Manual Control

For measuring duct leakage in residential & light commercial buildings.

Retrotec Model R31 consists of a Duc-Tester Module, a DM-2 Digital gauge and a 12 foot flex-duct with flanges for mounting on the return register. Case for DM-2A and grill mask dispenser not included.

New Home or Utility Standards

The Retrotec Duc-Tester is designed specifically to measure residential duct leakage. It can then be used to locate duct leaks and to measure the results of duct sealing. Use the Model R31 Duc-Tester to verify duct leakage for compliance with codes such as Title 24 in California. The typical 5 Ton air-conditioning system must have 120 cfm of leakage or less to pass California standards. The R31 will easily test any residential system because it will create 600 cfm which is 5 times more than that.

Retrotec Model R31 Specifications

Fan Flow (accuracy +/- 2.5 % with Retrotec DM-2 or Auto Correct software)

Maximum Flow in Free Air: 750 CFM 353 l/s 1273 m3/h
Maximum Flow at 25 Pascal with flex attached to a register: 530 CFM 250 l/s 901 m3/h
Minimum Flow at 25 Pascal test pressure with flex attached: 5 CFM 2.36 l/s 8.49 m3/h
Dimensions of Fan unit 14 × 14 × 12 in (35 × 35 × 30 cm)
Fan Motor: EBM backward curved impeller. 120V 2a or 240V 1a
Dimensions of Flex Duct 10” diameter. 15” to 10’ in length.
Dimensions of Carrying Case 25” × 14” × 15”

Calibration meets: Canadian CGSB-149.1-2002 & SuperE, USA ASTM E 779 – 03, European EN 13829 & CEN, UK TM-23 Energy Standards. NFPA 2001- 01, ISO 14520 and fire standards.

Specifications subject to change without notice. Infiltrometer is a registered trademark of Retrotec. Two (2) years parts and labor on fan unit

Operation

The Duc-Tester will pressurize or depressurize a duct system (with the air handler off) from the main return grille (or blower access opening). The rest of the register openings are taped shut. Duct pressure is measured by static probes in the supply ducts. Airflow is determined by reading flow directly from the DM-2. No computer is required. Setup, taping the registers and getting results takes less than 20 minutes in most homes. The Duc-Tester can also be used in conjunction with a blower door to neutralize duct leaks to indoors to that only duct leakage to outdoors is measured. 


 Related Items
Fantech SER 1504 SER1504 Energy Recovery Ventilators
Add To Cart
HomeGauge v4.3 Home Perfomance Energy Auditing Weatherization Inspection Software
$845.00
Add To Cart
Intec Quantum Insulation Blowing Machine
Contact for Price (877) 207-1244
Add To Cart
Review this item
Email this page to a friend

BBB Accreditation

AC Tool Supply on Manta

Lease Your Equipment


 

Infraspection Institute Conference

 

Ideal Electrical Datacomm Telecomm Wire Connectors
SafeWaze OSHA Safety Products
ACT-LOK Tamper Proof Security Fasteners
Gardner Bender Electrical Products
Fluke Test Measurment Thermal Camera Imagers
Knipex Pliers Quality Hand Tools
Retrotec Air Blower Door & Duct Systems
Extech Test & Measurment Instruments
Miller Fall Protection Arrest Prevention Safety
TSI Air Capture Flow Hoods Balometers
Alnor Air Flow Capture Hoods Balometer
Irwin Industrial Tools Saw Sawzall Blades Wood Auger Drill Bits
Skil Saw Power Tools
Bosch Cordless Power Tools
MK Diamond Blade Tile Saw
UEI clamp meters multimeters instruments
Rotozip
CST Berger Rotary Laser Level
AEMC Instruments Meter Tester
Stabila Rotary Level Laser Levels
David White Rotary Laser Levels Transit Level
Bacharach Combustion Gas Analyzers
Intec Insulation Machine Blowers
Leica Laser and GPS Systems
Cool Machines Blow in Insulation Blower
Krendl Blown in Insulation Blower Machines
Wohler Meters Analyzers Instruments

Home

About Us

Contact Us

My Account

 
 
 
Subscribe to our Newsletter.

Enter your Email address below and press the GO button.

 
 





Copyright © 2008 AC Tool Supply Inc. All Rights Reserved. e-Commerce Software powered by 3DCart.