Retrotec Q5E High Power Digital Modular Panel Air Blower Door Fan System with Modular Panels & Automatic Control - includes fan, guage, and door |
|
The Q5E is a commercial quality automated blower-door at an economy price. Use for super tight to super leaky houses, small commercial buildings or enclosures with 13.5 ft2 (1.2m2) of leakage or less.
DM-2A Automatic Dual Channel Micro-manometer
- Controls pressure or flow
- results without a computer!
- flow at any pressure, CFM50
- air-changes / hour
- leakage area, ELA
- air-flow / area
3300 Automatic Calibrated High Power variable frequency drive Fan
- 8000 cfm, even at 50 Hz
- runs on both 110 and 240 Volts
- computer controller built in
- 7 flow ranges for leakage measurement of super tight to super leaky buildings
| Fan Flow (accuracy +/- 5%, +/- 3% with Auto-Correct in Retrotec software) |
CFM |
Liters/~s~ |
m3/h |
| Maximum Flow in Free Air |
8,100 |
3,823 |
13,762 |
| Maximum Flow at 50 Pascal test pressure |
8,000 |
3,776 |
13,592 |
| At 50 Hz, NO power is lost due to variable frequency drive |
8,000 |
3,776 |
13,592 |
| Maximum Flow at 300 Pascal test pressure |
4,000 |
1,888 |
6,796 |
| Minimum Flow on Range Configuration C1 at 10 Pa |
38 |
18 |
65 |
| Dimensions |
inches |
cm |
| Fan height |
26 |
66 |
| Fan Depth |
9.5 |
24.1 |
| Fan Inlet Diameter |
22 |
56 |
| Panel height |
76.5 to 87 |
194 to 221 |
| Panel Case (included) |
31 × 30 x 7 77 × 76 × 18 |
| Panel Width |
32 to 48.75 |
81 to 124 |
| Fan weight |
37lb. |
16.8 kg. |
| Fan Motor |
2.0 hp, 22 amps at 120 V 14 amps at 240 Volts |
| Panel weight |
21.5 lb. |
9.8kg. |
Calibration meets: Canadian CGSB-149.1-2002 & SuperE, USA ASTM E 779 – 03, European EN 13829 & CEN, UK TM-23 Energy Standards, Rain Penetration Standards. NFPA 2001- 01, ISO 14520 and UBC-905 fire standards.
Specifications subject to change without notice. Infiltrometer is a registered trademark of Retrotec.
Optional Software Custom designed software is available from Retrotec for energy analysis, large building testing & fire enclosure integrity testing.
See literature on gauges, fans and panels for case options and accessories. |
|
|