Fluke 922 Airflow Micromanometer |
The Fluke 922 Airflow Micrmanometer gives HVAC technicians a feasible solution for troubleshooting ventilation issues, enabling measurements of differential pressure, velocity, and airflow with a single durable meter.
|
922 Airflow Micrmanometer Includes
922 Airflow Micrmanometer Features
-
Pressure drop measurements across HVAC machinery to extend equipment life and drive peak performance
-
Match ventilation to occupant loads
-
Monitor outdoor versus indoor pressure relationships in order to manage the building envelope
-
Promote indoor quality and comfort
-
Perform duct traversals for precise airflow readings
-
Differential and static pressure
-
Air velocity and flow
-
Convenient colored hoses allow easy interpretation of pressure readings
-
Bright backlit display
-
User defined duct size and shape for maximum accuracy
-
Resolution down to 0.001 in H2O
-
99 point data storage capacity
-
Minimum, Maximum, Average, and Hold functions for easy data analysis
-
Auto power off |
| Technical Specifications |
| Air Pressure |
| Range/Resolution/Accuracy |
± 4000 Pascals / 1 Pascal / ± 1 % + 1 Pascal |
| |
± 16 in H2O / 0.001 in H2O / ± 1 % + 0.01 in H2O |
| |
± 400 mm H2O / 0.1 mm H2O / ± 1 % + 0.1 mm H2O |
| |
± 40 mbar / 0.01 mbar / ± 1 % + 0.01 mbar |
| |
± 0.6 PSI / 0.0001 PSI / ± 1 % + 0.0001 PSI | |
| Air Velocity |
| Range/Resolution/Accuracy |
250 to 16,000 fpm / 1 fpm / ± 2.5 % of reading at 2000 fpm (10.00 m/s) |
| |
1 to 80 m/s / 0.001 m/s / ± 2.5 % of reading at 2000 fpm (10.00 m/s) | |
| Air Flow (Volume) |
| Range/Resolution/Accuracy |
0 to 99,999 cfm / 1 cfm / Accuracy is a function of velocity and duct size |
| |
0 to 99,999 / 1 m3/hr / Accuracy is a function of velocity and duct size |
| |
0 to 99,999 l/s / 1 l/s / Accuracy is a function of velocity and duct size | |
| Temperature |
| Range/Resolution/Accuracy |
0 °C to 50 °C / ± 1 % + 2 °C / 0.1 °C |
| |
32 °F to 122 °F / ± 1 % + 4 °F / 0.1 °F | |
| General Specifications |
| Operating Temperature |
| |
0 °C to +50 °C (+32 °F to +122 °F) | |
| Storage Temperature |
| |
-40 °C to +60 °C (-40 °F to +140 °F) | |
| Relative Humidity |
| |
0% to 90%, non-condensing | |
| IP Rating |
|
| Operating Altitude |
|
| Storage Altitude |
|
| EMI, RFI, EMC |
| |
Meets requirements for EN61326-1 | |
| Vibration |
|
| Max Pressure at Each Port |
|
| Data storage capacity |
|
| Warranty |
|
| Power, battery life |
|
| Battery Life |
| |
280 hours without backlight, 60 hours with backlight | | | |
|