Fluke 113 Digital MultiMeter Tester |
The Fluke 113 True RMS Utility Multimeter is designed for basic electrical testing.
|
|
The 113 Utility Multimeter enables utility users to easily do basic reconnect and meter set testing. The 113 is easy to use and can be used to repair almost any electrical problem. Significant improvements have been made with the 113 over the original Fluke 7-600, as well as other utility multimeters. Utilizing the Fluke VCHEK LoZ low impedance measurement function, simultaneous testing for voltage or continuity is a breeze. You can also perform diode testing with both manual and auto ranging capabilities. With many important features such as a large backlit display, conformance to the latest safety standards, the Fluke 113 is a neccessity for the utility users aresenal.
The Fluke 113 True RMS Utility Multimeter Features
-
VCHEK LoZ low impedance measurement function allows simultaneous testing for continuity or voltage
-
True RMS for accurate ac measurements on non linear loads
-
Large backlit display
-
Min/Max function for signal fluctuation recording
-
Diode test for testing general purpose silicon, germanium, and power diodes
-
Holster with probe holders
-
Manual and Auto ranging enhances user functionality
-
Meets Measurement Category CAT III 600 V and Category IV 300 V standards for a higher level of safety
-
Hands free flexibility using the optional TPAK magnetic hanger |
| Specifications |
| VCHECK 1,2 |
| Range |
6.000 V |
| |
60.00 V |
| |
600.0 V |
| Resolution |
0.001 V |
| |
0.01 V |
| |
0.1 V |
| Accuracy |
DC, 45 to 500 Hz:2.0 % + 3 |
| |
500 Hz to 1 kHz: 4.0 % + 3 | |
| Diode test 3 |
| Range |
2.000 V |
| Resolution |
0.001 V |
| Accuracy |
2.0 % + 3 | |
| Continuity3 |
| Range |
|
| Resolution |
|
| Accuracy |
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer | |
| Ω3 |
| Range |
600.0 Ω |
| |
6.000 kΩ |
| |
60.00 kΩ |
| Resolution |
0.1 Ω |
| |
0.001 kΩ |
| |
0.01 kΩ |
| Accuracy |
0.9 % + 2 |
| |
0.9 % + 1 |
| |
0.9 % + 1 | |
| Capacitance3 |
| Range |
1000 nF |
| |
10.00 μF |
| |
100.0 μF |
| |
9999 μF |
| Resolution |
1 nF |
| |
0.01 μF |
| |
0.1 μF |
| |
1 μF |
| Accuracy |
1.9 % + 2 |
| |
1.9 % + 2 |
| |
1.9 % + 2 |
| |
100 μF - 1000 μF: 1.9 % + 2 |
| |
> 1000 μF: 5 % + 20 | |
Notes: 1 All VChek voltage ranges are specified from 60 counts to 100 % of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. 2 Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. 3 After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity.
| Specifications |
| Maximum voltage between any terminal and earth ground |
|
| Display |
| |
3 3/4-digits, 6000 counts, updates 4/sec | |
| Operating temperature |
| |
-10 °C to 50 °C (14 °F to 122 °F) | |
| Storage temperature |
| |
-40 °C to 60 °C (-22 °F to 140 °F) | |
| Temperature coefficient |
| |
0.1 x (specified accuracy)/°C (< 18 °C or > 28 °C) | |
| Operating altitude |
|
| Storage altitude |
|
| Relative humidity |
| |
95 % to 30 °C |
| |
75 % to 40 °C |
| |
45 % to 50 °C | |
| Battery type |
| |
9 Volt Alkaline, ANSI 1604A / IEC 6F22 | |
| Battery life |
| |
Alkaline: 300 hours typical, without backlight | |
| Shock |
| |
1 Meter drop per IEC 61010-1-2001 | |
| Vibration |
| |
Per MIL-PRF-28800 for Class 2 instrument | |
| Size (HxWxL) |
| |
167.1 mm X 85.1 mm X 46.0 mm (6.58 in X 3.35 in X 1.81 in) | |
| Weight |
|
| < | |
|
|
 |
| Flir T420 T 420 Thermal Imaging Infrared Camera Sun Shield |
|
$50.00
|
| Add To Cart |
|
 |
| Flir T420 T 420 Thermal Imaging Infrared Camera High Temp. Option +1200°C/+2192°F |
|
Contact for Price (877) 207-1244
|
| Add To Cart |
|
 |
| Flir T420bx T 420 bx Thermal Imaging Infrared Camera High Temp. Option +1200°C/+2192°F |
|
Contact for Price (877) 207-1244
|
| Add To Cart |
|
|
|
|
Review this item
|
|
Email this page to a friend
|
|
|